anymodbus exposes a typed exception hierarchy where every class multi-inherits from the most natural standard-library or AnyIO base. Code that already catches ValueError, TimeoutError, OSError, anyio.BrokenResourceError, etc., picks up the right anymodbus exceptions without new except clauses.

Hierarchy

ModbusError                          (Exception)
├── ConfigurationError               (ValueError)        ← bad argument; nothing sent
├── ProtocolError                    (ValueError)        ← bad bytes on the wire
│   ├── ChecksumError
│   │   ├── CRCError                                     ← RTU CRC-16 mismatch
│   │   └── LRCError                                     ← ASCII LRC mismatch
│   ├── FrameError                                       ← truncated / malformed frame
│   └── UnexpectedResponseError                          ← reply doesn't answer the request
├── FrameTimeoutError                (TimeoutError)
├── ConnectionLostError              (anyio.BrokenResourceError)
│   └── TransportError               (OSError)           ← other OS-level port failure
├── BusClosedError                   (anyio.ClosedResourceError)
├── ModbusUnsupportedFunctionError   (NotImplementedError)
└── ModbusExceptionResponse          (slave-returned exception codes)
    ├── IllegalFunctionError
    ├── IllegalDataAddressError
    ├── IllegalDataValueError
    ├── SlaveDeviceFailureError
    ├── AcknowledgeError
    ├── SlaveDeviceBusyError
    ├── MemoryParityError
    ├── GatewayPathUnavailableError
    ├── GatewayTargetFailedToRespondError
    └── ModbusUnknownExceptionError                      ← any other code, e.g. legacy 0x07

ConfigurationError and ProtocolError both inherit ValueError, but the split is meaningful: ConfigurationError is raised before anything is sent (a bad BusConfig value, a slave address out of range, a register count above the spec maximum, a value that doesn't fit in a register), while ProtocolError is reserved for byte-level problems with what came back. Catching one independently of the other is usually what you want.

When to expect what

Situation Exception
BusConfig(request_timeout=-1) ConfigurationError
bus.slave(999) / bus.slave(0) ConfigurationError
read_holding_registers(0, count=200) ConfigurationError (raised before sending)
write_register(0, 70_000) ConfigurationError (raised before sending)
CRC mismatch on response (RTU) CRCError (a ChecksumError)
LRC mismatch on response (ASCII) LRCError (a ChecksumError)
Truncated or malformed response FrameError
Response FC, register count or write echo doesn't match the request UnexpectedResponseError
No response within request_timeout FrameTimeoutError
Slave returned exception code ModbusExceptionResponse subclass
USB cable yanked mid-transaction ConnectionLostError
Other OS error from the port (e.g. an unmapped anyserial.SerialError) TransportError (a ConnectionLostError and an OSError)
Bus closed and another task tries to use it BusClosedError

Under the default RetryPolicy, reads are retried on every ProtocolError and on FrameTimeoutError; writes are not retried.

An UnexpectedResponseError on a write means the slave did answer — the write may have been applied. A mismatched reply is most often a late reply to an earlier request; see late replies.

ModbusUnsupportedFunctionError is for the client declining to send a request whose function code it recognises but doesn't implement; no public method sends one today. A reply with such a function code is not this error: it is line damage (CRCError) or a confused slave (UnexpectedResponseError).

code_to_exception

For test fixtures and downstream library code that builds exception responses synthetically:

from anymodbus.exceptions import code_to_exception

raise code_to_exception(function_code=0x03, exception_code=0x02)
# → IllegalDataAddressError(...)